Speak with authority, quality is trustworthy.

Coolmay  >  AI - Page Sitemap  >  New plc simulator Suppliers for injection molding machinery
New plc simulator Suppliers for injection molding machinery

New plc simulator Suppliers for injection molding machinery
  • New plc simulator Suppliers for injection molding machinery
  • New plc simulator Suppliers for injection molding machinery

New plc simulator Suppliers for injection molding machinery

Adopting integral molding technology, the texture is solid and thick, the quality is safe and reliable, it is very convenient to disassemble, and it is not easy to bend after long-term use.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

Product Description:

The device includes functions below 

16DI/16DO, transistor output,

two channel analog input 0-5V

RS232, RS485 port

ModelCX3G-16MCX3G-24MCX3G-32MCX3G-48MCX3G-34MCX3G-64MCX3G-80M
Dimension85*90*36mm130*90*36mm200*90*36mm285*90*36mm
Cutout size77*99mm122*99mm192*99mm277*99mm
InstallationFixed hole installation and DIN-Rail (35mm )
FeaturesSupport interrupt, linear arc interpolation, PID auto-tuning. 32K program capacity, 32K retentive register
I/O levelInput: Passive NPN, public terminal isolated
Transistor output: NPN
Relay output: Normally open dry contact
Digital I/O8DI/8DO12DI/12DO16DI/16DO24DI/24DO18DI/16DO32DI/32DO40DI/40DO
DO typeTransistor(MT) or mixed(2T6R)Relay(MR) or transistor(MT) or mixed(MRT)
(Relay output: max load 5A/ transistor output: max load 500mA)
High speed countingSingle phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10 KHz
High speed pulse8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz
High-speed counting + high-speed pulse < 480KHz
Analog I/ONull6AI/4AO2AI8AI/4AO12AI/8AO16AI/8AO4AI/4AO
(optional)
AI typeType E/K/S/T/J thermocouple/ PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/
(optional)0~10V/ 0~5V/ 0-20mA/ 4-20mA

 -5V~5V/ -10V~10V(except for CX3G-16M)
AO type0~10V/ 0-~5V/ 0~20mA/ 4~20mA
(optional)-5~5V/ -10~10V (2DA for 1 minus temperature)
Default COM port1 Mini type B USB port, 1 Rs232(Interface terminal is mouse female port with 8 holes), 2 RS485 ports
OptionalDefault 2 RS485 ports can be customized asDefault 2 RS485 ports can be customized as 1 RS485, 1 RS232,
1 RS485, 1 RS232,CAN (2.0A/B) port is optional
or 1 RS485, 1 CAN (2.0A/B),
or 1 RS232, 1 CAN (2.0A/B)
CX3G-48M can add Ethernet port.
SoftwareCompatible with WORKS 2

Packing&Shipping

Packaging:The products will be under testing for 1-3 days and packed with carton box .

The package will include:
* 1 set of plc device+cables 
* Software and manuals are free of charge.They are available on our website or please contact our sales team for download links.
Note

 Shipping

By courier, door to door

For samples, the package will be delivered by DHL/UPS/FedEx/EMS express. Usually it will take 3-7 days to your location. 

 Post service

If you are not hurry but need economical delivery, we can go with packet channel. The delivery time depends on your location.

 Air shipping or by sea

If bulk order, the packages will be delivered by air shipping or by ship. 

 As some local customs require specific information for local import, please offer the information if you need the package to be sent to these countries.

India:  PAN or IEC or GST number

Peru: Tax number

Argentina: Tax number

Chile: Tax number

Brazil: CNPJ or CPF number

Bulgaria: Tax number for DHL shipping 


FAQ:

1.PLC can’t communication with PC (can’t monitor, can’t download)
There are several situations in which PLC and computer communication are not available. 
(1)PC serial port is broken, there is no way to use it.
(2)USB to 232 for laptop, the driver is not installed.
(3)PC serial port may leak, burn the PLC download protection resistor.
(4)Select wrong COM port on PC hardware.
(5)Can communicate, communication is unstable, check the line, try to replace the computer.
Summary: There are a variety of situations in which PLC can't download. It is recommended to use the replacement method to troubleshoot, such as replacing the computer, changing the download cable, replacing the PLC, etc.

2.PLC internal data (program) error 
Fault performance: data jumps, the program does not follow the normal execution. Possible causes:
(1)Use GX 8.52 or GX8.86 or Works 2 programming software not provided by our company, After replacing the software, turn off  
       


Company qualification:

New plc simulator Suppliers for injection molding machinery-1


Exquisite material selection, excellent workmanship, stable structure, reliable quality, wide range of applications, can be applied to different types of vehicles, such as: bicycles, tricycles, mountain bikes, folding bikes, children's cars, etc.
The surface is finely polished, the overall is smooth and bright, the edge is well-made, no burrs and does not hurt hands, it is safe and reliable to use, and the quality is trustworthy.
Selected high-quality materials, adopts the rib design, the guard plate is strong and strong, safe and reliable in use, it is a trustworthy chassis component product.
The material is carefully selected, the workmanship is fine, the appearance is beautiful, the quality is stable, and the surface has been specially treated with fine processing technology, the texture is uniform and thick, and the details are full of high-end quality.
Selected high-quality materials, refined through multiple complicated and fine processing techniques, with full and natural color, uniform and thick texture, safe and reliable quality, beautiful and practical, it is your ideal chassis parts product.
The product strictly upholds the high quality standards.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: