Model | CM520- 0.75/1.5KW | CM540- 0.75/1.5/4.0KW | CM540- 5.5/7.5/11KW |
Dimension | 86*114*143 | 118*156*185 | 247*160*176 |
L*W*Hmm | |||
Weight | 0.9kg | 2.0kg | 3.7kg |
Basic Function | |||
Maximum frequency | Vector control: 0.00~500.00Hz | ||
V/F control: 0.00~500.00Hz | |||
Carrier frequency | 0.8kHz~12kHz. The carrier frequency automatically adjusted based on the load features. | ||
Input frequency resolution | Digital setting: 0.01Hz | ||
Analog setting: Maximum frequency ×0.025% | |||
Control mode | Open-loop vector control (SVC), Closed-loop vector control (FVC), VF control. | ||
Startup torque | G type: 0.25Hz/150% (SVC), 0Hz/180%(FVC), P type: 0.5Hz/100% | ||
Speed range | 1:200(SVC), 1:1000(FVC) | ||
Speed stability accuracy | ±0.5%(SVC), ±0.02%(FVC) | ||
Torque control precision | ±5%(SVC)(above 10Hz), ±3%(FVC) | ||
Overload capacity | G type: 150% rated current 60s. 180% rated current 3s. | ||
P type: 120% rated current 60s. 150% rated current 3s. | |||
Torque boost | Automatic torque boost. Manual torque boost 0.1%~30.0% | ||
V/F curve | Five modes: Straight-line, Multi-points, Square V/F, V/F separation, V/F Semi-separation | ||
V/F Separation | Two modes: complete separation, semi-separation | ||
Ramp mode | Straight-line ramp and S-curve ramp. | ||
Four kinds of acceleration/deceleration time with the range of 0.0–6500.0s | |||
DC injection braking | DC braking frequency: 0.00Hz~maximum, braking time: 0.0s~36.0s. | ||
Braking action current value:0.0%~100.0% | |||
Jog control | Jog frequency: 0.00Hz~50.00Hz | ||
Jog acceleration and deceleration tome:0.0s~6500.0s | |||
Simple PLC, multistage speed operation | It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. | ||
Built-in PID | It can keep constant output voltage automatically when the mains voltage changes. | ||
Automatic voltage regulation(AVR) | Automatically maintain a constant output voltage when grid voltage changes. | ||
Over voltage/Over current loss of speed control | Automatic limit of the current and voltage during the operation, prevent frequent over current and over voltage | ||
Rapid current limit | Minimizing over-current fault and protect the normal operation of converter. | ||
Torque limit and control | "Excavator" characteristics, automatic limit of the torque during the operation, to prevent frequent over-current trip. Closed-loop vector mode torque control can be achieved. | ||
Other models: CM540-15/ 18.5/ 22KW, CM540- 30/ 37KW | |||
CM540-45/ 55/ 75KW, CM540-90/ 110KW | |||
CM540-132/ 160/ 185KW, CM540- 200/ 220/ 250/ 280KW | |||
CM540-315/ 350KW. | |||
The above models are all iron shells. For detailed dimensions, please contact us | |||
Detail info refer to: | |||
Coolmay CM520 VFD user manual Coolmay CM540-Inverter user manual |
Copyright © 2021 Guangzhou Weyes Network Technology Co., Ltd. | All Rights Reserved