Speak with authority, quality is trustworthy.

Coolmay  >  AI - Page Sitemap  >  Best plc switch factory for printing machinery
Best plc switch factory for printing machinery

Best plc switch factory for printing machinery
  • Best plc switch factory for printing machinery
  • Best plc switch factory for printing machinery

Best plc switch factory for printing machinery

Coolmay PLC applies military-grade chip,faster operating speed and strong anti jamming capability.The inputs and outputs apply opto-isolator.Analog i/o,RS232 and RS485 areintegrated.It is a new control concept in functions,cost-saving and conveniences.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

Product Description:

 The device includes functions below 

16DI/16DO, transistor output,

one channel analog input 4-20mA

RS232, RS485 port

ModelCX3G-16MCX3G-24MCX3G-32MCX3G-48MCX3G-34MCX3G-64MCX3G-80M
Dimension85*90*36mm130*90*36mm200*90*36mm285*90*36mm
Cutout size77*99mm122*99mm192*99mm277*99mm
InstallationFixed hole installation and DIN-Rail (35mm )
FeaturesSupport interrupt, linear arc interpolation, PID auto-tuning. 32K program capacity, 32K retentive register
I/O levelInput: Passive NPN, public terminal isolated
Transistor output: NPN
Relay output: Normally open dry contact
Digital I/O8DI/8DO12DI/12DO16DI/16DO24DI/24DO18DI/16DO32DI/32DO40DI/40DO
DO typeTransistor(MT) or mixed(2T6R)Relay(MR) or transistor(MT) or mixed(MRT)
(Relay output: max load 5A/ transistor output: max load 500mA)
High speed countingSingle phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10 KHz
High speed pulse8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz
High-speed counting + high-speed pulse < 480KHz
Analog I/ONull6AI/4AO2AI8AI/4AO12AI/8AO16AI/8AO4AI/4AO
(optional)
AI typeType E/K/S/T/J thermocouple/ PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/
(optional)0~10V/ 0~5V/ 0-20mA/ 4-20mA

 -5V~5V/ -10V~10V(except for CX3G-16M)
AO type0~10V/ 0-~5V/ 0~20mA/ 4~20mA
(optional)-5~5V/ -10~10V (2DA for 1 minus temperature)
Default COM port1 Mini type B USB port, 1 Rs232(Interface terminal is mouse female port with 8 holes), 2 RS485 ports
OptionalDefault 2 RS485 ports can be customized asDefault 2 RS485 ports can be customized as 1 RS485, 1 RS232,
1 RS485, 1 RS232,CAN (2.0A/B) port is optional
or 1 RS485, 1 CAN (2.0A/B),
or 1 RS232, 1 CAN (2.0A/B)
CX3G-48M can add Ethernet port.
SoftwareCompatible with WORKS 2

Packing&Shipping

Packaging:The products will be under testing for 1-3 days and packed with carton box .

The package will include:
* 1 set of plc device+cables 
* Software and manuals are free of charge.They are available on our website or please contact our sales team for download links.
Note

 Shipping

By courier, door to door

For samples, the package will be delivered by DHL/UPS/FedEx/EMS express. Usually it will take 3-7 days to your location. 

 Post service

If you are not hurry but need economical delivery, we can go with packet channel. The delivery time depends on your location.

 Air shipping or by sea

If bulk order, the packages will be delivered by air shipping or by ship. 

 As some local customs require specific information for local import, please offer the information if you need the package to be sent to these countries.

India:  PAN or IEC or GST number

Peru: Tax number

Argentina: Tax number

Chile: Tax number

Brazil: CNPJ or CPF number

Bulgaria: Tax number for DHL shipping 


FAQ:

1.PLC can’t communication with PC (can’t monitor, can’t download)
There are several situations in which PLC and computer communication are not available. 
(1)PC serial port is broken, there is no way to use it.
(2)USB to 232 for laptop, the driver is not installed.
(3)PC serial port may leak, burn the PLC download protection resistor.
(4)Select wrong COM port on PC hardware.
(5)Can communicate, communication is unstable, check the line, try to replace the computer.
Summary: There are a variety of situations in which PLC can't download. It is recommended to use the replacement method to troubleshoot, such as replacing the computer, changing the download cable, replacing the PLC, etc.

2.PLC internal data (program) error 
Fault performance: data jumps, the program does not follow the normal execution. Possible causes:
(1)Use GX 8.52 or GX8.86 or Works 2 programming software not provided by our company, After replacing the software, turn off  
       


Company qualification:

Best plc switch factory for printing machinery-1



Advanced testing equipment is used in the production of Coolmay . The product will be tested under multimeter, Battery component detection system, and cell tester. The product has a high-hardness surface
Coolmay has been tested for guaranteed safety. It has passed China's CCEE, GSG and CEMC, Japan's S-MARK and VCCI, Germany's VDE, and Canada's CSA. It can withstand the corrosion of acid, alkali, and other chemical substances
Coolmay is manufactured with high-quality electric components. All of the materials used in these electric components have excellent mechanical strength, heat resistance, electric performance, and easy to shape. It conforms to the standards of EN, ASTM, DIN, BS, JIS, etc
Coolmay is generally tested under a simulated environment. These tests may include fatigue testing for electronic components and thermal insulation performance testing for materials. Adopting high-quality imported stainless steel, it has a long service life
The quality tests for Coolmay mainly include seven aspects: its allowable deviation, finish appearance, seam limit, paint quality, water content, formaldehyde emission, and harmful substance content. Its stainless steel raw materials make it easy to clean
This product has electromagnetic compatibility. EMC testings are performed in it manufacturing to a wide range of EMC standards such as EMC Directive 2014/30/EU. It receives popularity among customers from Europe, America, Middle East, and so on
Chat Online
Chat Online
Chat Online inputting...
Sign in with: